• Deutsch
  • Engish
Application
CEL-Immersion heaters fort heating of water (car wash and drinking water) Material of tube: highly corrosion-proof special steel (alloy), material-N°. 2.4858, Material of screw had: special steel,admissibleworking pressure: 10 bars Depth of immers. Mm
Power con sumption KW
Specificload Area density W / cm²
Unheated length from mm on Appr. Weight Kg SAP-N° Order N°
Without cover System of Protection IP 00, Volatge: 3 / N / PE ~ 230 / 400 V Elektricsupply: Flat plug 6.3 - 0.8 DIN 2644 (bei Cel 605 + Cel 606 screw rail clips) 175 2 12,5 30 0,5 118218 CEL 601
235 3 12,5 30 0,6 118219 CEL 602
335 4,5 12,5 30 0,7 118220CEL 603
435 6 12,5 30 0,9 118231 CEL 604
525 7,5 12,5 30 1,1 118232 CEL 605
625 9 12,5 30 1,3 11833 CEL 606
With temperature delimter,with fixed setting at 155º,with plastic cap,System of Protection IP 44,Voltage:3 / N / PE ~ 50 bis 60 Hz, 400 VElektric supply: screw rail clips) 175 2 12,5 30 0,85 118234 CEL 611
235 3 12,5 30 0,95 118235 CEL 612
335 4,5 12,5 30 1,05 118236 CEL 613
435 6 12,5 30 1,25 118237 CEL 614
525 7,5 12,5 30 1,45 118238 CEL 615
625 9 12,5 30 1,65 118239 CEL 616
With Thermo regulator,adjustable from 0 bis 100º C,with plastic cap,System of Protection IP 44,Voltage:3 / N / PE ~ 50 bis 60 Hz, 400 VElektric supply: screw rail clips) 175 2 12,5 30 0,85 118240 CEL 621
235 3 12,5 30 0,95 118241 CEL 622
335 4,5 12,5 30 1,05 118242 CEL 623
435 6 12,5 30 1,25 118243 CEL 624
525 7,5 12,5 30 1,45 118244 CEL 625
625 9 12,5 30 1,65 118245 CEL 626
With Thermo regulator,adjustable up to 75º C,and temperature delimter withfixed setting at 95º Cwith plastic cap,System of Protection IP 44,Voltage:3 / N / PE ~ 50 bis 60 Hz, 400 V* 1 / N / PE ~ 50 bis 60 Hz, 230 VElektric supply: screw rail clips) 335 2 12,5* 100 0,85 118246 CEL 631
335 3 12,5 100 0,95 118247 CEL 632
400 4,5 12,5 100 1,05 118248 CEL 633
500 6 12,5 100 1,25 118249 CEL 634
600 7,5 12,5 100 1,45 118250 CEL 635
700 9 12,5 100 1,65 118251 CEL 636
CEL- Immersions heaters for heating of oil(degreasing installations asn similar liqiuds, air in motion)material for immersion heaters and threaded screw had G 1 ½ B:special steel,
Depth of
immersmm
Power con sumptionkW Specific loadW /    cm² Appr.WeightKg SAP-N° OrderN°
Without capSystem of protection IP 00,Max.temp. of tube jacket: 420º C,admissible working pressure: 10 bar;Voltage:Flat plug 6.3 - 0.8 DIN 2644(for Cel 514 screw rail clips) 460 1,5 2,3 0,8 118211 CEL 502
885 3 2,3 1,6 118212 CEL 503
400 3 5,2 0,8 118214 CEL 505
630 4,5 4,8 1,2 118215 CEL 506
800 6 4,9 1,6 118216 CEL 507
885 9 6,6 1,6 118217 CEL 514
AttentionAccording to the legislation for the protection of maschines it is obligatory to use a temperature delimiter for the functioning of immersion heaters in pressure reservoirs.
SAP-N° Order N°
Counternutfrom Brass 118252 CEL 902
Reducing adapter R2" / 1,5 / from Brass 118253 CEL 925
Hexagon socket screw keyto be mounted on the face 118255 CEL 941
Metallcapfor System of prot. IP 54 Suitable for CEL60 and CEL5 118213 CEL 940